Main Features |
Input signal: RTD, Ohm, TC, mV | ||||
High measuring accuracy | |||||
3 wires sensor connection | |||||
PC software sets range, failure status, damping and units | |||||
Standard DIN B sensor head mounted | |||||
Input Parameters |
Type | Model | Measuring Range | Min. Measuring Range | |
Thermal Resistance | PT100 | -200 to 850℃ | 10K | ||
CU50 | -50 to 150℃ | 10K | |||
PT1000 | -200 to 250℃ | 10K | |||
Resistance Signal | 0~350R | 5 to 350R | 5R | ||
0~4000R | 10 to 4000R | 10R | |||
Thermocouple | B | 400 to 1820℃ | 500K | ||
E | -200 to 915℃ | 50K | |||
J | -200 to 1200℃ | 50K | |||
K | -200 to 1372℃ | 50K | |||
N | -2070 to 1300℃ | 50K | |||
R | -50 to 1760℃ | 500K | |||
S | -0 to 1760℃ | 500K | |||
T | -200 to 400℃ | 50K | |||
Voltage Signal | mV | -10~75mV | 5mV | ||
Output Parameters |
Current Output |
/ | |||
Signal Range | 4~20mA | ||||
Transmission Characteristic | It's linear with temperature | ||||
Transmission Accuracy | 0.1%FS | ||||
Response Time (Settable) | 0~60s | ||||
Load (Current Output) | (V-8)/0.023(Ohm) | ||||
Load Stability | 0.01%F.S/100 Ohm | ||||
Sensor Failure Alarm Output | 3.8 or 23mA | ||||
Standard Parameters |
Power | / | |||
Power Supply | 12~35V DC | ||||
Reverse Voltage Protection | Yes | ||||
The Influence of Power Supply Voltage Variation On Accuracy | <0.005%/V standard 24V | ||||
Warm-up Time | 5minutes | ||||
Environment
|
Operation Temperature | -40 to +85℃ | |||
Calibration Temperature | 20 to 28℃ | ||||
Temperature Effect | 0.01%/℃ standard 25℃ | ||||
Climatic Conditions | <95%RH (no condensation) | ||||
Anti-seismic Property | Accord with GLCharacteristic2 | ||||
EMC | EN61 326 ClassB | ||||
Protection Degree | IP68/IP00 | ||||
Dimensions |
Structure Size | Φ44*24mm | |||
Bolt Center | 33~36mm | ||||
Material | PVC | ||||
Weight | About 45g |
(unit: mm)
Input
Output
1. Specializing in the field of measurement for 16 years
2. Cooperated with a number of top 500 energy companies
3. About ANCN:
*R&D and production building under construction
*Production system area of 4000 square meters
*Marketing system area of 600 square meters
*R&D system area of 2000 square meters
4. TOP10 pressure sensor brands in China
5. 3A credit enterprise Honesty and Reliability
6. National "Specialized in special new" little giant
7. Annual sales reach 300,000 units Products sold worldwide
If the product shape and performance parameters have special requirements, the company provides customization.